PRODUCTS

OPHTHALMIC MICROSURGICAL BLADES

is a NANO CUT Chemically Eitched Automatic Surgical Blade. They are made with NO MANUAL TOUCH (AUTOMATIC) to give Precise cut.

Ask for Quote

HYALURONIC ACID SOLUTION PFS

is intended for use during surgery in the anterior and posterior segments of the human eye. It is designed to create and maintain anterior chamber depth and visibility, protect corneal endothelial cells and other intraocular tissues, minimize interaction between tissues during surgical manipulation. Also preserves tissue integrity and good visibility when used to fill the anterior and posterior segment of eye.

SODIUM HYALURANATE WITH CHONDRIOTIN SULFAPHATE PFS

iOCUCOAT - Ophthalmic Viscosurgical Device has an intermediate cohesive/dispersive index (CDI). It is a strerile, non-pyrogenic, viscoelastic solution of a highly purified non-inflammatory medium molecular weight fraction of sodium hyaluronate and sodium chondroitin sulphate. iOcuCoat maintains a deep chamber during anterior segment surgeries, enhances visualization during the surgical procedure, and protects the corneal endhothelium and other ocular tissues. The viscoelasticity of the solution maintains the normal position of the vitereous face, thus preventing formation of a postoperative flat chamber. It is designed to create and maintain space, to protech the corenal endothelium and other introcular tissues and to manipulate tissues during surgery.


HYDROXYPROPLY METHYLCELLULOSE OPHTHALMIC SOLUTION PFS

is clear isotonic solution, contains Hydroxyptoply Methyalcellulose USP. It is high retention and dispersive viscoelastic solution which is widely used for phacoemulsification / cataract surgery. Its Unique properties offers good space maintenance and excellent tissue protection throughout the procedure.

OPHTHALMIC DRAPES (SMS FABRIC)

is made from nonwoven SMS fabrics (A lightweight, It is Strong with good Softness, Excellent in tensile strength & Barrier Properties) with or without liquid collection pouch, used in ophthalmology surgery.


BALANCED SALT SOLUTION (IRRIGATION SOLUTION)

is sterile balance sodium solution (BSS), and also as an isotonic to the tissues of the eyes and is a lint-free solution containing essential ions for normal cell metabolism.

is used to irrigate anterior chamber, extraocular muscles, or lacrimal system, wash out lens fragments during cataract extraction, irrigate eyes during vitrectomy, and moisten cornea. Irrigating solutions may preserve the corneal endothelial structure and function, and keep lens clear. It is used as the perfusion solution in cataract extraction, intraocular lens implantation and extraction, and other ophthalmic surgeries. It may also be used in perfusion of ear, nose and throat.


OPHTHALMIC CANNULA (DISPOSABLES)

is a manual ophthalmic disposable cannula which is handheld device intended to aid or perform ophthalmic surgical procedures


iSURGEON KIT

iSURGEON KIT comes with high fabric SMS material for comfortable wear and complete hygine. The items included inside the Kit helps surgeons for easy access during the surgery. We provide kit with CUSTOMISATION as per clients need

DIAGONISTIC STRIPS

We manufacture the Best Quality Diagnostic Strips with Whatman Filter Paper for precise results. We take due care in Packing and Sterility of the product which gives complete saftey about the product.

SURGICAL SPEARS

and are manufactured with high quality, lint free PVA sheets and cellulose sheets. and are cut very precisely for better absorption during the surgery.

Ophthalmic Forceps Ophthalmic Speculums iPulator IOL Manipulator iScissor Ophthalmic Scissors iHolder Ophthalmic Needle Holders iHook Ophthalmic Hooks

PACK OF 5

Slit Keratome (Bevel up and Down) 1.8mm to 5.5mm

Lance Tip 15, 30 and 45 Degree

MVR 19, 20 and 24 Guage

Crescent 45 Degree 19G and 20G

Depth Indicator at (1.5mm, 1.75mm and 2.00mm) in SLIT (KERATOME) Knives and Lance Tip

Precise Placement with Laser Marking

Helps in Evaluating Pentration Levels

Nano Cut

We are masters in producing Zero Manual Touch Blades so that the surgeons gets better cut with smooth edges

Sharp Cutting surgical blades

  • Sodium Hyaluronate Ophthalmic Solution 1% w/v in 0.8ml, 1ml,1.5ml,1.6ml,1.8ml and 2.0ml PFS<
  • Sodium Hyaluronate Ophthalmic Solution 1.2% w/v in 0.8ml, 1ml,1.5ml,1.6ml,1.8ml and 2.0ml PFS
  • Sodium Hyaluronate Ophthalmic Solution 1.4% w/v in 0.8ml, 1ml,1.5ml,1.6ml,1.8ml and 2.0ml PFS
  • Sodium Hyaluronate Ophthalmic Solution 1.6% w/v in 0.8ml, 1ml,1.5ml,1.6ml,1.8ml and 2.0ml PFS
  • Sodium Hyaluronate Ophthalmic Solution 1.8% w/v in 0.8ml, 1ml,1.5ml,1.6ml,1.8ml and 2.0ml PFS
  • Sodium Hyaluronate Ophthalmic Solution 2.4% w/v in 0.8ml, 1ml,1.5ml,1.6ml,1.8ml and 2.0ml PFS
  • Sodium Hyaluronate Ophthalmic Solution 3.0% w/v in 0.8ml, 1ml,1.5ml,1.6ml,1.8ml and 2.0ml PFS

Molecular Weight : 1.8 to 2.2 Million Dalton

Viscosity at Rest: upto 310000 to 1000000 mPas

pH : 6.8 – 7.6

Osmolality : 270– 400 mOsm/Kg

Raw Material : Non-Animal Origin

BD Glass Syringe

Bubble Free

Imported Viscoelastic Cannula

Blister Packing

No refrigeration required - Store at Room Temperature

iOCUCOAT - Sodium Hyaluronate (3% w/v) with Sodium Chondroitin Sulfate (4% w/v) Ophthalmic Solution in 1ml PFS

iOCUCOAT+ - Sodium Hyaluronate (2% w/v) with Sodium Chondroitin Sulfate (2% w/v) Ophthalmic Solution in 1ml PFS

Molecular Weight : 1.6 to 2.2 Million Dalton

Viscosity at Rest: upto 200000 to 300000 mPas

pH : 6.8 – 7.6

Osmolality : 320– 370 mOsm/Kg

Raw Material : Sodium Hyaluronate - Non-Animal Origin

: Sodium Chondroitin Sulfate - Non-Bovine Origin

BD Glass Syringe

Clear (Opaque) Solution - Not Pale Yellow

Bubble Free

Blister Packing

No refrigeration required - Store at Room Temperature

AdipHPMCicing elit

iVISTA VIDA Hydroxypropyl Methylcellulose Ophthalmic Solution 2% w/v (HPMC) in 2ml and 3ml

iVISTA VIDA+ Hydroxypropyl Methylcellulose Ophthalmic Solution 2.4% w/v (HPMC) in 2ml and 3ml

AdipHPMCicing elit

Viscosity at Rest : 4000 –10000 mPas

pH : 6.8 – 7.6

Osmolality : 270– 400 mOsm/Kg

Raw Material : Non-Animal Origin

Premium Glass Syringe

Clear (Opaque) Solution

Blister Packing

No refrigeration required - Store at Room Temperature

Adipdrapesicing elit

Eye Incise Drape Mini, with attach Drain Pouch, Size 15 x 10 cm, Adhesive Area 10 x 10 cm

Eye Drape Plain, Size 60 x 40 cm, Incise Area 7 x 9 cm with drain pouch & eyelid holders

Drape Plain, Size 70 x 70 cm, Incise Area 7 x 9 cm with drain pouch & eyelid holders

Eye Drape Plain, Size 100 x 70 cm, Incise Area 7 x 9 cm with drain pouch & eyelid holders

Phaco Drape Size 100 x 70 cm Incise area 7 x 9 cm with drain pouch and eyelid holders

Eye Drape Plain, Size 100 x 100 cm, Incise Area 7 x 9 cm with drain pouch & eyelid holders

Eye Drape Plain, Size 100 x 120 cm, Incise Area 6 x 17 cm with drain pouch & eyelid holders

Eye Drape Plain, Size 150 x 160 cm, Incise Area 6 x 17 cm with drain pouch & eyelid holders

Adipdrapesicing elit

Top Grade SMS FABRIC

Automatic Stiching

43 Grade SMS Fabric

Comes with high grade Tape for sticking

Smooth SMS Fabric

Imported Gum for incision Area - Perfect Stciking

Good Quality Tape for Sticking the Drape

Precise Cutting of Drape

Adipbssicing elit

Plastic (PP) Euro Head Bottle - 500ml

Plastic (PP) Pods (Eye Wash) - 5ml Pod

Plastic (PP) Pods (Eye Wash) - 10ml Pod

Adipbssicing elit

Each mL Consists of

Sodium Chloride BP........0.64% w/v

Potassium Chloride BP........0.75% w/v

Magnesium Chloride Hexahydrate BP........0.03% w/v

Calcium Chloride Dihydrate BP........0.048% w/v

Sodium Citrate Dihydrate BP........0.17% w/v

Sodium Hydroxide BP to adjust PH

Water for Injections BP qs

It Hydrates and protects tissue and cells during all ophthalmic procedures

Used for irrigation during various surgical procedures of the eyes, ears, nose and/or throat

Maintains integrity of endothelial tissue

quivalent composition to aqueous humor

It contains no preservative and should not be used for more than one patient

Adipcannulaicing elit

Viscoelastic and Irrigation Cannula

Hydrodissection and Cystostome Cannula

Lens Removal and Cortex Cannula

Anesthesia Needles and Lacrimal Cannula

Air Injection and Irrigating Cannula

Lasik and Vitroretinal Cannula

Bimanual and Glucoma Cannula

Adipcannulaicing elit

Lacrimal Intubation Set - Regular

Lacrimal Intubation Set - with Olive Tip

DCR Set - Straight

DCR Set - Angled

High Grade Steel

Box Pack of 20

High Lubricated Glue

Micro size spatulated tip

Adipsgicing elit

SMMS Fabric is composed of two layers of spun bonded fabric and two layers of Melt blown fabric. With good tensile strength, high filtration and remarkable softness.

Sizes Available - S,M,L,XL

Also AVAILABLE in other Materials

Polyprrolene Fabric (PP)

Spunlace Non Woven Fabric

Microcare Fabric - Level-IV Gown

Adipsgicing elit

KIT 1

SMMS - Wraparound Surgical Gown Cap Face Mask with Visior Shoe Cover Latex Gloves Hand Towel

KIT 2

SMMS - Wraparound Surgical Gown Patients Drape Face Mask Surgeon’s Cap Shoe Cover Plain Sheet Mayo's Trolley cover Sterile Gloves Goggles Hand Towels

High Grade SMMS Fabric

SMMS fabric protects from fluid penetration

Gowns are fixed with four ties system

Comfortable Wear and Disposal

Overview - Fluorescein Sodium Strip is made of filter paper impregnated with highly pure fluorescein sodium solution. Sterilized by oxirane, it is nontoxic, free of side effects and non-irritative to eye. It is safe and reliable

Use – It is the most commonly used diagnostic strip used to visualize defects or abrasions in the corneal epithelium by staining the areas of cellular loss. Also useful for evaluating hard contact lens fitting & applanation tonometry.

Size - Each strip includes 1 mg fluorescein sodium. 1 strip / pouch, 100 pouches/box

Overview - Schirmer Tear Test Strips are made of Whatman No 41 filter paper. It has a calibrated scale printed on the strip, on which a color line made of fluorescent dye will co-migrate with the tear flow. An easier and more precise reading will be provided. These strips are individually wrapped and are gauged so they can be easily read.

Use – It is used to measure the amount of tear production. The Schirmer test is based upon mechanical reflex stimulation of the tear production and is actually a test of reflex tear production when performed without anesthesia

Size - 1 strip / pouch, 100 pouches/box

Overview - Lissamine Green Strip work by staining the cornea blue upon instillation. This causes "speckling" of the cornea, which gives the doctor immediate indication of any dry patches, as well as any muco-deficient or damaged corneal cells. Most importantly, it does not sting the eye like Rose Bengal, and a white light or blue light can be used on the slit lamp during detection.

Use – Used for diagnosing muco-deficient or damaged corneal cells

Size - 1 strip / pouch, 100 pouches/box

Adipspearsicing elit

PVA Surgical Spears are constructed of PVAc.

100% fibre and particle free.

Designed to manipulate tissue during LASIK surgery and corneal refractive procedures.

Lint free, high density PVA formulation and virtually particulate free.

Fiber-free construction will not introduce lint into the surgical site.

Easily trimmed to any size.

Sterilized by gamma radiation.

Highly absorbent, single use, fast wicking and packaged sterile.

Maintains rigidity during wicking process.

Adipspearsicing elit

Constructed of the finest compressed cellulose sponge material securely molded to a Polypropylene handle.

High soaking capacity cellulose sponge spears mounted on plastic handles.

High volume fast wicking action for absorption of blood and fluids within the operational field.

Fast wicking, micropoint absorbent.

Extremely strong, will not tear or shred.

Sterilized by ETO.

Stainless Steel (SS410 & SS420)

The whole range is availble in Stainless Steel (Medical Grade)

Titanium (Reusable)

The whole range is availble in High Grade Reusable Titanium

Ophthalmic Forceps

Barraquer | Capsulorhexis | Lims | Utara and many more

Ophthalmic Speculum

Wire Solid Blade | Kartz | Liberman | Mudrock and many more

iPulator
IOL Manipulator

Jaffe | Jaffe-Bechert | Akahoshi Nucleus | Intracapsular and many more

iScissor
Ophthalmic Scissors

Westcott | Castroviejo Corneal | Vannas and many more

iHolder
Needle Holder

Barraquer | Castroviejo | Troutman | Side Curved and many more

iHook
Ophthalmic Hooks

Sinskey | Helveston | Retinal Detachment and many more

iChop
Phaco Chopper

Akahoshi | Claw Phaco | Phaco Chopper and many more

Adipsticing elit

Lorem ipsum dolor sit amet, consectetur adipsticing elit, sed do eiusmod tempor incididunt ut labore

Adipsticing elit

Lorem ipsum dolor sit amet, consectetur adipsticing elit, sed do eiusmod tempor incididunt ut labore

Anim pariatur cliche reprehenderit, enim eiusmod high life accusamus terry richardson ad squid. 3 wolf moon officia aute, non cupidatat skateboard dolor brunch. Food truck quinoa nesciunt laborum eiusmod. Brunch 3 wolf moon tempor.